Product image 'CORDSTRIPPER' system

CORDSTRIPPER system

For quick, safe and convenient preparation and uncovering of steel cable belts.

Basic equipment for optimum operation

The following components are required for the initial configuration of a CORDSTRIPPER system:

Our products at a glance

Produktbild 'CORDSTRIPPER'

CORDSTRIPPER

Product image: Blade set for 'CORDSTRIPPER'

Knives for CORDSTRIPPER

Produktfoto - Powerwinch CS inklusive Führungsschiene

POWERWINCH CS

Produktfoto - Powerwinch CS inklusive Führungsschiene

Guide rail for POWERWINCH CS

Product sheet

Contact us

Further products

Discover more products from WAGENER VULCANIZERS.

Available as the DTP270, DTP330, and DTP380

Switch cabinet

  • Color display with digital display of the target and actual values of Vulcanizing time and vulcanizing temperature

  • Display of the remaining curing time (timer)

  • Signal tone after the vulcanization time has elapsed

  • Display of the current consumption in amperes of the 3 phases per
    heating platePrecise temperature measurement in the heating plates via PT100Temperature difference monitoring with ±2.5°C of all connectedconnected heating platesController tolerance approx. 1% of the set value (e.g. at 145°C approx. 1.5°C)Switch cabinet for 1 or 2 pairs of heating plates (2 or 4-fold), Input 32 or 63AConnection of electric pressure pumps for three-phase currentManual operation possibleElectrical connections according to CEE, Harting (UL/CSA)Applicable directives DIN EN, DIN VDE, IECOptionally also available with the data logging system “SPLICE-
    WATCH” data logging system

  • Precise temperature measurement in the heating plates via PT100

  • Temperature difference monitoring with ±2.5°C of all connectedconnected heating plates

  • Controller tolerance approx. 1% of the set value (e.g. at 145°C approx. 1.5°C)

  • Switch cabinet for 1 or 2 pairs of heating plates (2 or 4-fold), Input 32 or 63A

  • Connection of electric pressure pumps for three-phase current

  • Manual operation possible

  • Electrical connections according to CEE, Harting (UL/CSA)

  • Applicable directives DIN EN, DIN VDE, IEC

  • Optionally also available with the data logging system “SPLICE-
    WATCH” data logging system

Product image control box
Cookie Consent with Real Cookie Banner